Op 4 fire extinguisher its characteristic service life. Fire extinguisher expiration date - what affects this parameter and how to find it

Now it is powder fire extinguishers that are considered universal devices that are actively used to eliminate fires of various classes (A, B, C, E). The masters who tested various fire extinguishers, compared their characteristics, indicators, managed to determine that powder fire extinguishers are the most effective devices.

Powder fire extinguishers can be successfully operated in a wide temperature range. At the same time, its consumer properties remain stable. After all, the composition includes a special powder, which, when in contact with fire, becomes foam. The foam barrier prevents the penetration of oxygen, so the fire goes out smoothly.

Purpose of powder fire extinguisher OP-4

Powder fire extinguisher OP-4 can be filled with various types of powders. Based on which modification is chosen, this fire extinguisher can be used to extinguish organic and solid objects, combustible raw materials, gaseous mixtures, as well as devices that are energized.

The main purpose of powder fire extinguishers OP-4 is the rapid extinguishing of various types of metals, structures, including this raw material. After all, some types of metals can burn without a constant supply of oxygen.

Powder fire extinguishers OP-4 have a unique design, including:

1. an integral case, in which a special powder is placed to eliminate the source of ignition;

2. siphon tube;

3.special powder spray gun;

4.Additional components to adjust the flow, optimize the distance.

The mixture that is part of the fire extinguisher is in a compressed state, under a certain pressure. This is what allows you to supply the mixture to the required distance, to extinguish without worrying about your own health.

Application of powder fire extinguisher OP-4

  • various technical means, transport;
  • fire shields, which are equipped with industrial complexes, enterprises, factories, office blocks, residential premises and houses;
  • various divisions.

Such an extensive industry of using a powder fire extinguisher is due to the benefits that the consumer receives:

  • The total weight, dimensions of the powder fire extinguisher are small, so there are no difficulties with installation, dismantling, operation.
  • The weight of the charge is large enough, so it can be operated for a long time, to eliminate a larger source of ignition.
  • There will be no problems with operation, storage, if you first study the instructions, technical passport.

In order to activate the fire extinguisher, it is necessary to remove the seal immediately before the source of ignition, remove the pin, and also direct the nozzle directly onto the fire. There are no delays, so a quick response will help you prevent the fire from spreading. A fire extinguisher that has already been used can be recharged.

Technical characteristics of the powder fire extinguisher OP-4

1. The total weight of the fire extinguishing mixture, which is part of the OP-4 fire extinguisher, is about 4 kg.

2. A fully equipped fire extinguisher weighs about 6.5 kg.

3. The working jet can be blown up to a distance of about 3 meters.

4. The period of active action of the fire extinguisher is 10 seconds.

5.Storage time can be up to 10 years. But it is very important at the same time to strictly observe the rules of storage, take into account the features of operation.

The price of a powder fire extinguisher OP-4 in St. Petersburg

Now the cost of powder fire extinguishers OP-4 is diverse in St. Petersburg. Quite strongly it depends on such aspects as marking, technical characteristics, equipment. Regular customers, wholesale customers can count on certain discounts, the amount of which can be obtained directly from consultants and managers.

But in order for your expenses to be justified, you definitely need to carefully choose a modification. If you find it difficult to navigate on your own, involve the staff.

Certificate for fire extinguisher OP-4

Each OP-4 powder fire extinguisher must pass the certification and testing process. The results are recorded in the relevant documents.

In the process of manufacturing powder fire extinguishers, manufacturers are guided by the regulations defined by GOSTs. For example, GOSTs 2.601, R 51057, R 51017 are used in the preparation of markings and labels.

Testing is carried out in accordance with the normative act NPB-199, which spells out the basics and features.

In addition to the documents evidencing certification, the kit also includes technical passports and warranty cards.

Passport for fire extinguisher OP-4

The passport included in the set is prepared in accordance with the current standards and norms. The document contains information on the main technical indicators, features of storage and operation. All the information provided is true, there are no ambiguous interpretations. Therefore, there will be no difficulties either during the study or during operation.

Additional data must be entered into the passport if not only a fire extinguisher is purchased, but also additional accessories for it.

Expiration date of powder fire extinguisher OP-4

The shelf life of a powder fire extinguisher can be up to ten years. But in order for it to remain operational, function without problems, it is imperative to follow the prescribed storage rules.

There are a large number of types and modifications of fire extinguishers designed to extinguish a wide variety of fires, the ignition sources of which can be combustible materials, chemical reactions, etc.

For example, if we take then, it is more compact compared to OP 5 and OP 8. But, accordingly, it contains less extinguishing agent, although OP 4 does not lose in any way to OP 5 in terms of extinguishing duration.

This fire extinguisher is less than twice as heavy as OP 2, which weighs 3.5 kg. It is also almost two times lighter than OP 8, whose weight is 12.0-12.6 kg. Considering its ability to carry, this mass is optimal for the use of OP 4 in any office.

How to use it?

In principle, there is nothing easier than learning how to use such a fire extinguisher. First you need to break the seal. After that, you need to remove the check, which protects the fire extinguisher from accidental operation. Then you should go to the source of ignition, point the bell at it and press the lever.

Establishments must constantly check how other workers know how to use fire extinguishers, which is very important, as many lives can depend on it.

You should not treat a fire extinguisher as an over-safety tool, because once you put out a small fire, you can prevent a big catastrophe.

The fire extinguisher is designed to extinguish burning liquids, solids, gases and electrical installations under voltage up to 1000 V. The price of the fire extinguisher OP-4 z (ABC) is in the "Price list" section.

The Voliks company offers to buy this fire extinguisher wholesale or retail by self-delivery or with delivery in Moscow, the region and Russia. Upon shipment of goods, we provide a full package of documents and necessary certificates. All questions of interest can be asked by phone or mail indicated in the "Contacts" section.

Photos of the fire extinguisher OP-4

* The photo of the fire extinguisher on the site may differ from the real one. Regardless of the manufacturer, the technical characteristics of the model correspond to the presented name. All products are certified.

Technical characteristics of the powder fire extinguisher OP-4:

  • Mass of fire extinguishing agent, kg - 4+-0.2
  • Working pressure in the body, MPa - 1.5+-0.1
  • Duration of fire extinguishing agent supply, s, not less than - 10
  • Exhaust air jet length, m, not less than - 3.0
  • Overall dimensions, mm, no more - 430х150
  • Weight kg, no more - 6.3
  • Operating temperature range, ºС - from -40 to +50

Leakage of propellant gas is not allowed. Operation and storage temperature from minus 40 C to plus 50 C. Probability of failure-free operation of a fire extinguisher between inspections, once every three years, not less than 0.95. Assigned service life of a fire extinguisher, years - 5.

The masters who tested various fire extinguishers, compared their characteristics, indicators, managed to determine that powder fire extinguishers are the most effective devices.

Powder fire extinguishers can be successfully operated in a wide temperature range. At the same time, its consumer properties remain stable. After all, the composition includes a special powder, which, when in contact with fire, becomes foam. The foam barrier prevents the penetration of oxygen, so the fire goes out smoothly.

Purpose of powder fire extinguisher OP-4

Powder fire extinguisher OP-4 can be filled with various types of powders. Based on which modification is chosen, this fire extinguisher can be used to extinguish organic and solid objects, combustible raw materials, gaseous mixtures, as well as devices that are energized.

The main purpose of powder fire extinguishers OP-4 is the rapid extinguishing of various types of metals, structures, including this raw material. After all, some types of metals can burn without a constant supply of oxygen.


Powder fire extinguishers OP-4 have a unique design, including:

1. an integral case, in which a special powder is placed to eliminate the source of ignition;

3.special powder spray gun;

4.Additional components to adjust the flow, optimize the distance.

The mixture that is part of the fire extinguisher is in a compressed state, under a certain pressure. This is what allows you to supply the mixture to the required distance, to extinguish without worrying about your own health.

Free legal advice:


Application of powder fire extinguisher OP-4

  • various technical means, transport;
  • fire shields, which are equipped with industrial complexes, enterprises, factories, office blocks, residential premises and houses;
  • various divisions.

Such an extensive industry of using a powder fire extinguisher is due to the benefits that the consumer receives:

  • The total weight, dimensions of the powder fire extinguisher are small, so there are no difficulties with installation, dismantling, operation.
  • The weight of the charge is large enough, so it can be operated for a long time, to eliminate a larger source of ignition.
  • There will be no problems with operation, storage, if you first study the instructions, technical passport.

In order to activate the fire extinguisher, it is necessary to remove the seal immediately before the source of ignition, remove the pin, and also direct the nozzle directly onto the fire. There are no delays, so a quick response will help you prevent the fire from spreading. A fire extinguisher that has already been used can be recharged.

Technical characteristics of the powder fire extinguisher OP-4

1. The total weight of the fire extinguishing mixture, which is part of the OP-4 fire extinguisher, is about 4 kg.

2. A fully equipped fire extinguisher weighs about 6.5 kg.

Free legal advice:


3. The working jet can be blown up to a distance of about 3 meters.

4. The period of active action of the fire extinguisher is 10 seconds.

5.Storage time can be up to 10 years. But it is very important at the same time to strictly observe the rules of storage, take into account the features of operation.

The price of a powder fire extinguisher OP-4 in St. Petersburg

Now the cost of powder fire extinguishers OP-4 is diverse in St. Petersburg. Quite strongly it depends on such aspects as marking, technical characteristics, equipment. Regular customers, wholesale customers can count on certain discounts, the amount of which can be obtained directly from consultants and managers.

But in order for your expenses to be justified, you definitely need to carefully choose a modification. If you find it difficult to navigate on your own, involve the staff.

Certificate for fire extinguisher OP-4

Each OP-4 powder fire extinguisher must pass the certification and testing process. The results are recorded in the relevant documents.

Free legal advice:


In the process of manufacturing powder fire extinguishers, manufacturers are guided by the regulations defined by GOSTs. For example, GOSTs 2.601, R 51057, R are used in the preparation of markings, labels.

Testing is carried out in accordance with the normative act NPB-199, which spells out the basics and features.

In addition to the documents evidencing certification, the kit also includes technical passports and warranty cards.

Passport for fire extinguisher OP-4

The passport included in the set is prepared in accordance with the current standards and norms. The document contains information on the main technical indicators, features of storage and operation. All the information provided is true, there are no ambiguous interpretations. Therefore, there will be no difficulties either during the study or during operation.

Additional data must be entered into the passport if not only a fire extinguisher is purchased, but also additional accessories for it.

Free legal advice:


Expiration date of powder fire extinguisher OP-4

The shelf life of a powder fire extinguisher can be up to ten years. But in order for it to remain operational, function without problems, it is imperative to follow the prescribed storage rules.

Expiration date of the fire extinguisher OP-4

The powder fire extinguisher OP-4, which belongs to the primary fire extinguishing means, can be called one of the most common fire extinguishers that are equipped with the following premises:

Shops and warehouses,

Shelf life of powder fire extinguisher OP-4

Over the years of operation, it has been established that the shelf life of the OP-4 powder fire extinguisher from the date of manufacture (indicated on the cylinder and in the accompanying documentation) is at least 10 years. This has been confirmed by both manufacturers and operators. These results can be achieved if the following requirements are met:

Free legal advice:


2. Checking the pressure in the cylinder (at least 1 time in 3 months. In case of detecting a pressure drop of the mixture by at least 10% of the set values, take measures to eliminate the causes of the pressure drop and refill),

3. Avoid sudden temperature changes (it is forbidden to store OP-4 near heaters, radiators, heaters, boilers, etc.)

What class of fires can OP-4 fight?

If you follow the instructions and accompanying documentation for the OP-4 powder fire extinguisher, it is designed to effectively fight fires of the following hazard categories at the initial stage:

Test fire extinguisher OP-4 in conditions close to real

Free legal advice:


Scientific Innovation Center for Construction and Fire Safety

Expiry date of dry powder fire extinguisher

A powder fire extinguisher allows you to fight fires of class A, B, C, BC. Depending on the model and volume, it can be filled with various types of powder and pumped with various gases (nitrogen, air or carbon dioxide). The extinguishing process occurs due to the release of powder under high pressure.

The unit can be operated in a wide temperature range (minimum temperature -50, and maximum, respectively, +50 degrees Celsius). They are easy to use and convenient.

Speaking about the shelf life of a powder fire extinguisher op 4, it must be remembered that it must be regularly recharged (once every five years), and the gas pressure in the device must be checked - once every three months, at least. Regularly fulfilling all requirements for storage and operation, a powder fire extinguisher will last 10 years. The release date and all the characteristics of the device are indicated in its passport.

The manufacturer can guarantee accurate and uninterrupted operation of the device within 12 months from the date of sale of the fire extinguisher, but not more than one and a half years from the date of its release. The devices must not be installed near heating devices; direct sunlight and precipitation should not fall on it. The maximum allowable storage temperature of the device is +50 degrees.

If you violate the storage conditions, as a result, you will not be provided with warranty service.

Free legal advice:


The maximum duration of a powder fire extinguisher is seconds. Powder supply is intermittent. Moreover, it is recommended to keep a fire extinguisher no further than 3-4 meters from the source of direct ignition. This device is not intended for extinguishing substances that can burn without access to air. Its power and the duration of powder supply directly depend on the volume.

Powder fire extinguishers are widely used in everyday life, at enterprises and in cars. Fire extinguishers with a volume of 1 to 8 liters are considered portable, while those with a volume of 50 to 100 liters are mobile fire extinguishers. It is possible to recharge the cylinder at special stations, or by contacting a certified company providing such services.

Powder fire extinguisher OP-4

Powder fire extinguishers are the most versatile devices designed to extinguish almost all classes of fires and are used over a wide temperature range. A limitation for their use are fires initiated by the ignition of materials that burn without access to oxygen, for example, alkali or alkaline earth metals.

One of the most popular models of powder fire extinguishers is OP-4 (z) - ABCE. If we decipher this abbreviation, we get: a powder fire extinguisher with a nominal mass of fire extinguishing powder of 4 kg, pumping, designed to extinguish fires of classes A, B, C and E.

Free legal advice:


Where is the powder fire extinguisher OP-4 used?

Due to the technical parameters and versatility of the fire extinguishing powder, OP-4 is indispensable for extinguishing all types of fires, except for burning metals (class D):

  • class A - combustion of solid objects (paper, wood, plastic, etc.);
  • class B - combustion of liquids, both soluble and insoluble in water (gasoline, alcohol, glycerin, etc.);
  • class C - combustion of gases (propane, hydrogen, household gas, etc.);
  • class E - burning equipment and installations under high current.

The use of OP-4 at such facilities as:

  • public buildings;
  • warehouses;
  • industrial enterprises;
  • domestic buildings and premises;
  • delivery trucks;
  • minibuses,

efficient and cost-effective, which is proven in practice.

Specifications OP-4

Operation of the fire extinguisher OP-4 is possible in a wide temperature range - from minus 40°С to plus 50°С.

It is required to recharge the devices once every 5 years, the service life is 10 years.

Free legal advice:


These powder fire extinguishers are easy to use, easy to maintain, effective and safe for humans in fire fighting.

The technical parameters of OP-4 (h) are as follows:

  1. Capacity - 5 l.
  2. The mass of the charge of OTV is 4.0 ± 0.2 kg / l.
  3. Working pressure - 1.4±0.2 MPa.
  4. The duration of the powder supply in case of fire is 10 seconds.
  5. Jet length - 3 m.
  6. The mass of the cylinder is 6 kg. Dimensions - 13 cm diameter, 42 cm height.
  7. Fire extinguishing capacity - 2A (fire class A), 55V (class B).

The principle of OTV release is displacement under the action of excess pressure, which creates a working gas (carbon dioxide).

How to store powder fire extinguisher OP-4

To store OP-4 indoors, the devices are installed on the floor on special stands or mounted on the wall using brackets. As a rule, only a hose-bell and a passport for the product are included with the fire extinguisher, so brackets, stands and other necessary related products are purchased separately.

The location of the OP is chosen based on the points of GOST No. 12.4.009. The care of the OP consists in periodic checking of the appearance of the device, the strength of the fasteners, the integrity of the seal, and the removal of dust and contaminants from the surface.

Free legal advice:


A more detailed diagnosis of the serviceability of the fire extinguisher is carried out during the quarterly maintenance of the device. Once a year, the maintenance company conducts an opening of the OP and evaluates the parameters of the fire extinguisher. Recharging OP-4 is necessary every 5 years of operation or without fail after activating the device.

How to activate the powder fire extinguisher OP-4 (h)

In order to activate the fire extinguisher OP-4 of the pumping type in case of fire, it is necessary to perform the following actions:

  • direct the nozzle, from which the fire extinguishing agent will come out, to the source of ignition;
  • break the seal;
  • pull out the pin of the fire extinguisher, which is a metal rod bent at the end into a ring;
  • push the lever.

After activating the fire extinguisher, start extinguishing the fire.

Expiration dates of fire extinguishers are an important safety issue

The actual service life of a fire extinguisher is affected by several related factors, but there is also a service life approved by the standard, it depends on the type of fire extinguisher chosen. Based on these indicators, the maximum duration of storage of fire extinguishers at work, in public places, in cars is determined.

Free legal advice:


What are fire extinguishers

The classification defines the following types of fire extinguishers:

  • Powder. They are marked OP. The index indicates the mass of the charge (OP 5 - 5 kg, OP 4 - 4 kg). A powder fire extinguisher is a universal device suitable for any type of fire - at electrical installations up to 1 kW, at oil storage facilities, when cars ignite, in warehouses. The main extinguishing agent in a fire extinguisher is powder. According to the type of ejection, the jets are divided into gas generating (G), injection (Z), compressed air cylinder (B).
  • Carbon dioxide. They are labeled OU. The index also indicates the mass of the charge in the cylinder (OS 5 - 5 kg). A carbon dioxide fire extinguisher is used in electrical installations up to 1 kW in urban electric transport, on railway electric locomotives. The active substance is carbon dioxide under pressure, which varies depending on the ambient temperature.
  • Air foam. ORP are marked. They have two types of active ingredients - chemical, foam consists of water and alkali, air-mechanical - from a foaming agent and water. Cannot be used in electrical installations. Use only for small fires of solids and flammable liquids.
  • self-acting modules. OSB marked. The active substance is a powder. Designed for fires of any class, they are also used in electrical installations up to 5 kW. A self-acting fire extinguisher is installed permanently in rooms with increased fire hazard, it is activated automatically, under the influence of smoke and flame. The OSB fire extinguisher has access to the most secluded corners of the room, inaccessible to people. Recommended for small areas.
  • Water. They are labeled OTV. The active ingredient is water. They are used for class A fires, and if there are additives in the water, then class B.

Powder and carbon dioxide differ in the volume of cylinders. They are portable - 1-10 liters and mobile - 20-100 liters. Mobile devices are often paired cylinders mounted on a special mobile cart.

What do the regulations say

  1. The shelf life of a powder fire extinguisher is 10 years for a cylinder and 5 years for a charge. At the same time, cylinders installed at the factory, in public places, require an annual scheduled check, which is indicated by a special note in their passport. Specialists of the fire supervision service check the condition of the active substance by opening individual cylinders from the whole batch. According to its results, an assessment of the state is given and, if necessary, fire extinguishers are sent for recharging.
  2. The shelf life of carbon dioxide type fire extinguishers is 10–15 years, depending on storage conditions. They also require an annual charge quality check. Specialists perform it by weighing the cylinder, determining the gas leakage and the condition of the shut-off valves. A quarterly inspection is also carried out at the production site, which determines the installation site, the appearance of fire extinguishers. Every five years, the charge of a carbon dioxide fire extinguisher is renewed by completely discharging and cleaning from the remnants of the fire extinguishing agent. After that, a complete inspection of the integrity of the cylinder and a check of the tightness of the body are carried out.
  3. Storage of water and foam type fire extinguishers - no more than 1 year, after which they must be replaced. This type of device cannot be recharged.

Most types are also better to replace right away than to recharge. The cost of charging is most often equal to the cost of a new fire extinguisher.

Car fire extinguisher - what is the expiration date?

The rules for operating a car require a fire extinguisher in its cabin or at least in the trunk.

The ideal option is powder compact models - OP 2 for 2 kg of active substance, which does not contradict the requirements of the Rules. For greater security, it is better to give preference to a metal case over a plastic one.

Free legal advice:


When buying, you need to pay attention to the seal, it must be intact, as well as the certificate and expiration date (5 years per charge). The advantages of powder models are a medium-strength jet, compactness, and low price. The disadvantage is that when used, the powder clogs the territory and surface.

If you choose a carbon dioxide fire extinguisher, then its volume should not be less than the powder one, and these are models OU 2 and OU 3, by 2 and 3 kg of charge, respectively. The advantage of gas-type models is a good pressure of the working jet and complete evaporation of the active substance. The disadvantage is the toxicity of the substance, which requires work with gloves or with a special gasket and a low range of the working jet - 50–70 degrees.

The expiration date of a car fire extinguisher corresponds to its type:

  • Powder - 10 years for a cylinder, 2 years for a charge;
  • Carbon dioxide - 15–20 years per cylinder, 5 years per charge.

How to store

According to the Code of Rules, a fire extinguisher is required to be carried in the cabin, mounted on a bracket with a lock and a lock. The best place for these purposes is the passenger door, from there the cylinder can be easily removed and used in case of fire.

If the car is stored in an unheated garage or on the street, then it is better to use a powder type fire extinguisher. Its storage temperature ranges from -40 to +50 ˚С.

Free legal advice:


But in the summer, it is better to avoid direct sunlight on the cylinder, for which you should protect the car with a special shading, reflective curtain. In carbon dioxide models, as the ambient temperature rises, the working pressure inside the cylinder also increases, which must be taken into account.

Can I store a fire extinguisher in the trunk

If there was no place for a fire extinguisher in the cabin, then it is better to fix it in the trunk than not to have it at all. In this case, recharging will need to be done more often, due to the direct influence of the environment on the cylinder, at least once a year.

Any deviation in the operating conditions of the car and storage of the fire extinguisher affects its shelf life. Of course, no one will determine the performance by eye. If a fire extinguisher in a car is required only to pass a technical inspection and throw dust in the eyes of traffic police, then it is only important to follow the correct choice of model and warranty periods on the fire extinguisher passport. For those who care about their own safety, it is better to do device replacement and routine inspections more often.

What to do with an expired fire extinguisher

This question is asked by most motorists, having learned that the service life has come to an end.

Due to the extreme operating conditions of a car fire extinguisher, it rarely lends itself to recharging. It is better to buy a new model, with high reliability guarantees. But the old one can be used as a training projectile.

Free legal advice:


It is no secret that few drivers have tried to use a fire extinguisher in practice. So there will be a chance to master this technique on your own, at the same time checking the veracity of the declared characteristics - the length and density of the jet, the operating time.

You can refill the fire extinguisher, using it as a stationary device in the garage, in the house, in the country. Ideally, it's best to take your end-of-life device to a recycling center if one is available in your area of ​​residence.

How to find out the characteristics of a fire extinguisher yourself

All important parameters of the fire extinguisher are indicated in its passport, fixed directly on the cylinder. Mandatory of them are:

  • Factory number stamped directly on the passport;
  • manufacturer;
  • date of manufacture;
  • Working and test pressure;
  • The volume and weight of the balloon;
  • Factory OTK stamp.

When charging is performed, its date is affixed to the passport, and a control seal is installed on the cylinder.

Before buying a new fire extinguisher, it is better to immediately look at the device passport in order to determine for yourself how long it is guaranteed to serve you in the future. This knowledge will help to correctly determine the service life, recharge time, insuring against the questions of regulatory authorities - the fire safety department, traffic police services, and reduce the likelihood of fines.

Free legal advice:


The service life of each fire cylinder is determined by the developers and indicated in the technical documentation and passport. Each serviceable container has a seal, a blocking device and a marking.

Shelf life of fire protection equipment

  • powder - 10 years;
  • carbon dioxide -years;
  • air-foam (ORP) - 10 years.

Vehicle fire protection equipment has the following expiration dates:

  • freight and passenger transport - OU-2, OP-2 weighing at least 2 kg;
  • minibuses - OP-2, buses - OP-2, OP-5;
  • tank trucks - OP-5.

All fire extinguishers are classified according to the following criteria:

  • according to the method of action (automatic and manual);
  • the principle of the device;
  • according to the volume of the cylinder (from 1.6 to 400 kg);
  • by appointment;
  • on the design of launchers.

Characteristics of powder fire extinguishers:

  • used to extinguish fires of different classes;
  • are used when cutting off the flame in electrical equipment connected to a high-voltage line up to 1000 V;
  • adaptability to a wide temperature range (from -50° to +50°);
  • response time from 6 to 15 seconds;
  • the length of the ejection of the substance is from 2 to 6 m.

The disadvantage is the substance itself - the powder. After use, it clogs the room and objects.

Free legal advice:


Characteristics of carbon dioxide fire extinguishers:

  • are used for extinguishing liquid and gaseous substances, in case of fire in transport;
  • to cut off the flame in electrical equipment with a voltage not exceeding 1000 V;
  • wide temperature range (from -40° to +50°);
  • response time from 6 to 30 seconds;
  • the length of the substance ejection is 2-4 m.

Characteristics of air-foam fire extinguishers:

  • used to extinguish solid and liquid combustible substances;
  • have a long spray time (20-60 seconds);
  • temperature range is from +5° to +50°;
  • the length of the substance ejection is from 3 to 4 m.
  • limitation when extinguishing electrical equipment;
  • freezing at low temperatures;
  • unsuitability for extinguishing the flame of substances that react violently to water.

Check frequency

There are two types of inspections of fire extinguishers: quarterly and annual.

Inspection of the availability and serviceability of carbon dioxide type fire extinguishing equipment is carried out once a year. By weighing the cylinder and calculating the flame-extinguishing mass, the suitability is checked.

Powder cylinders are controlled at least once every 5 years by selective withdrawal and opening. The district inspector conducts scheduled inspections, which include inspection of the body of fire extinguishers. In addition to monitoring the expiration date, the fireman checks the integrity of the seals, the condition of the metal coating, the functioning of the shut-off device and the lock.

Free legal advice:


If damage is detected, the cylinder is sent for MOT (maintenance).

During the quarterly inspection, the presence, location and appearance of fire fighting equipment are mainly controlled.

Organizations specializing in the maintenance of fire extinguishing equipment perform the following types of work:

  • inspect the hull and trigger devices;
  • check with instruments;
  • perform performance tests;
  • reload;
  • repair worn parts.

Fire extinguishers for vehicles, regardless of type, are subject to annual inspection:

  • powder are diagnosed using indicators;
  • carbon dioxide - according to the results of weighing and calculating the mass of the extinguishing agent.

What to do when the expiration date has expired

All fire extinguishing cylinders must be recharged in a timely manner:

  • in case of using the funds;
  • if the leakage parameters of the composition exceed the permissible level;
  • during scheduled reloading.

Service life before recharging fire extinguishers:

  • carbon dioxide - 1 time in 5 years;
  • powder - 1 time in 5 years;
  • air-foam - 1 time per year;
  • water - 1 time per year.

Vehicle fire extinguishers installed outside the cab must be recharged once a year due to the direct influence of the environment on the body. Other transport fire extinguishers are subject to maintenance at least once every 2 years.

In reality, models with a foam or aerosol system do not recharge for various reasons:

  • design features and principles of operation of some models;
  • the cost of recharging will cost about the same as a new fire extinguisher.

End-of-life cylinders remain as training material or are scrapped. Water-based and foam-type fillers can be discharged into the production waste outlet by diluting with plenty of water.

Other types of extinguishing agents must be professionally removed from the hull. It is not allowed to drain them into drainage systems, as the composition contains chemical elements that contribute to environmental pollution.

Therefore, in almost all cities there are points for receiving used fire extinguishing devices, where decommissioned cylinders should be handed over. There they are disassembled and sent for recycling.

Regulatory requirements SP 9.13130.2009 - the document contains sections:

  • Set of rules;
  • Fire fighting equipment;
  • fire extinguishers;
  • Operating requirements.
  • operational terms of fire extinguishing means;
  • types of cylinders and their purpose;
  • procedure for inspections and maintenance;
  • packaging and marking;
  • storage conditions and rules of use;
  • types of fire-fighting equipment used for vehicles.

Operating instructions

Powder extinguishing media

  1. It is not allowed to place heating elements near the cylinders.
  2. The temperature regime of storage must correspond to the temperature range of the fire extinguisher (-40°+50°).
  3. Recharging should be carried out on time and only in organizations specializing in the maintenance of fire fighting equipment. The maintenance information must indicate the type of powder being used.
  4. Transportation is allowed by all modes of transport.
    • hull condition;
    • working gas pressure (indicator readings should be in the green field in the range of 8-12 kgf / cm2);
    • quenching state.

The hull is subject to re-examination every 5 years.

Carbon dioxide extinguishing media

  1. The basic requirements for operation are indicated on the marking of the fire extinguisher body.
  2. Fire extinguishing devices should be located in prominent places or on a specially equipped fire shield.
  3. It is allowed to use a fire extinguisher at a distance of 1 meter to suppress the spread of fire in electrical appliances with a voltage of not more than 1000 V.
  4. Reloading should be carried out on time only in organizations specializing in the maintenance of fire fighting equipment. Returned cylinders must have a check and a seal.
  5. When using a fire extinguisher, you must follow the safety rules. Low temperature (-50°-70°) can injure parts of the body.
  6. After extinguishing the fire, it is necessary to ventilate the room from combustion products and carbon dioxide vapors.
  7. According to regulatory requirements, it is necessary to periodically monitor the working condition of fire extinguishing equipment. Allowable charge leakage should not exceed 50 g.
  8. Re-examination of the hull is carried out once every 10 years.
  9. There are no restrictions on the type of transportation of fire extinguishing equipment.

Air-foam type fire extinguishers

  1. The basic requirements for operation are indicated on the marking of the fire extinguisher body.
  2. Fire extinguishing devices should be located in prominent places or on a specially equipped fire shield.
  3. It is not allowed to place heating elements or sunlight near the cylinders.
  4. Recharging should be carried out on time only in organizations specializing in the maintenance of fire equipment. Returned cylinders must have a check and a seal.
  5. There are no restrictions on the type of transportation of fire extinguishing equipment. In frosty weather, it is allowed to transport cylinders without filler.
  6. Each cylinder is subject to periodic inspection:
    • hull condition;
    • working gas pressure (indicator readings should be in the green field in the range of 8-12 kgf / cm2).

Cancel reply

HQsignal - video surveillance systems. All rights reserved. Copying of material is possible with the placement of an active link to our source site.


Budget price 435r.

435r.

bottle 5 l

Universal in terms of characteristics and volume powder fire extinguisher. Attractive price-performance ratio. Suitable for equipping premises, construction sites, vehicles.


An effective fire extinguisher for extinguishing all classes of fires, with the widest range of applications. Fire extinguisher OP-4 can be installed as a primary fire extinguishing agent on cars and trucks, on special professional equipment, rural tractors and combines. OP-4 is suitable for service in most climatic zones - operation is possible at negative ambient temperatures up to forty degrees. Therefore, the use of a fire extinguisher OP-4 (h) for the acquisition of shields at construction sites, gas stations, and other street objects of urban social and commercial infrastructure is not prohibited.

The extinguishing agent is completely out of the cylinder in ten seconds. During extinguishing, it is recommended not to release all the powder at once, but by opening the valve for two to three seconds, distribute the charge of the fire extinguisher over the entire fire area. According to modern fire safety standards, it is believed that in standard-type rooms for two hundred meters of area, one product with a volume of five liters is enough. Depending on the class of the object, the number of fire extinguishers may vary.

Serviceability is determined by the reading of the pressure gauge, the pointer must be placed in the green indicator zone. If the pressure gauge needle goes into the red zone, then the fire extinguisher must be recharged. Pressure gauges are checked annually, during the entire five-year service life. The OP-4 fire extinguisher is charged with powder of different quality, which must be indicated on the label. Cheap powders are not suitable for class A fires (wood, cardboard).

Technical characteristics of the fire extinguisher OP-4

The products are certified, the OP-4 fire extinguisher has a mandatory fire safety certificate.